Type 1001 I/P & E/P Transducers
  • 0.1% accuracy typical
  • Closed loop pressure feedback control minimizes effects of vibration, temperature, supply pressure and mounting angle
  • Built-in volume booster provides flows up to 12 SCFM
  • Easy access zero and span adjustment
  • Damping pot prevents over shoot and “hunting”
  • Low air consumption
  • Mounts at any angle (NEMA 3R limited)
  • Compact and lightweight
  • Virtually no sensitivity to supply pressure changes
  • Removable orifice for easy maintenance
Product Detail:
The Type 1001 is a patented family of electro-pneumatic instruments that is used to reduce a supply pressure to a regulated output pressure which is directly proportional to a two-wire current or three-wire voltage input. This design incorporates closed loop sensing of the output pressure to achieve excellent accuracy and vibration stability. It also features a unique damping circuit which can be adjusted to prevent overshoot and actuator “hunting.” Model selection includes General Purpose (NEMA 1), Rainproof (NEMA 3R), and Watertight/Corrosion Resistant (NEMA 4X). NEMA 4X models are also explosion-proof, and all models are intrinsically safe.
Part Numbers:
Create Part Number:
9
6
X
XX
X
0
XX
6
  NEMA 1, General Purpose2 Enclosures
7
  NEMA 3R, Rainproof2
8
  NEMA 4X, Water-tight, Dust-tight, Corrosion Resistant, & Explosion Proof
XX
  See/Input Output Matrix Below1 Calibration
0
  None Agency Approvals
1
  Factory Mutual & CSA Explosion Proof
00
None Options
06
Fluorocarbon Elastomeric Diaphragm
notes to nomenclature:
1. Transducer operating in the voltage mode (E/P), can be adjusted with the “span” potentiometer for any input between 0-10 VDC. The input range is limited to a minimum 4VDC difference between 100% and 0% Input voltage.
2. Standard NEMA 1 enclosure is conversion coated only. Standard NEMA 3R and NEMA 4X enclosures are epoxy painted.

T1001 Standard Input/Output Matrix
psig
0-5
0-15
0-30
0-60
0-100
1-17
3-15
3-27
6-30
3-9
9-15
0-
2
0-
120
4-20mA
19
6
20
8
9
5
2
3
4
0
1
13
7
10-50 mA
11
16
85
98
89
15
12
87
14
10
90
91
17
0-5 VDC
21
26
18
28
29
25
22
35
24
30
31
92
27
1-5 VDC
81
36
86
38
39
97
32
33
34
50
41
93
37
1-9 VDC
82
46
40
48
49
45
42
43
44
60
51
94
47
1-10 VDC
83
56
96
58
59
55
52
53
54
88
61
95
57
0-10 VDC
84
66
70
68
69
65
62
63
64
80
99
23
67
Options:
T1001 Accessories-Kits Part Number
Panel Mounting Kit
010135-000
Valve Mounting Kit *** 010134-000
2" Pipe Mounting Kit (Valve Mounting Kit is required) 010143-000
DIN Rail Adapter 010115-000
Cover for Locking Device Kit (for NEMA 4X enclosure only) 010136-000
Type 1 Orifice with Buna-N O-rings* 010137-000
Type 1 Orifice with Viton O-rings* 010137-002
Type 2 Orifice with Buna-N O-rings** 010137-001
Type 2 Orifice with Viton O-rings** 010137-003
Filter Kit, 60 microns 010139-000
Filter Kit, Coalescing, 0.1 microns 010140-000
Filter Element Kit (for coalescing filter, package of 10) 010141-000
Hirschman® Connector Kit (Din 43 650-A)
(3 prong plug, O-ring sealed)
010142-000
Pressure Gauge Kit, 15 PSI 010138-000
Pressure Gauge Kit, 30 PSI 010138-001
Pressure Gauge Kit, 60 PSI 010138-002
Pressure Gauge Kit, 160 PSI 010138-003
* Type 1 Kits to be used with Ø based output units and 1-17 psig unit.
** Type 2 Kits to be used with all other units.
*** Supplied standard with Nema 4X

T-1001 Specials Table
Part Number
Input
Output
Comments
962-145-000
4-20 mA
20-100 kPa
NEMA 1
962-146-000
20-100 kPa
NEMA 3R
962-148-000
0-200 kPa
NEMA 1

 